Symptom

  • SIP2 machines that previously worked well, stopped working once SIP2 configuration info was copied across to the Sandbox instance.

Applies to

  • WorldShare Circulation, SIP2, Sandbox

Resolution

SIP2 lookup matches on IP address only, not institution. Nothing stops the same IP being used for both production and sandbox, so if the sandbox record is returned instead of production (lookup order isn't guaranteed), authentication fails.

  1. Check if the sandbox IP matches a production IP.
  2. If it does, change the sandbox IP to one not used in production.
  3. Re-test.

Additional information

If you're setting up Sandbox SIP2 settings, use an IP address that's different from any of your production IPs. Reusing a production IP in sandbox can cause your production SIP2 devices to fail intermittently.